Era Elite® 2940nm Er:YAG Laser
Four Optical Modules. One Device. Fitzpatrick I–VI.
Every depth of resurfacing on one platform: sub-ablative renewal, full-field ablation, hybrid fractional remodeling. Each 300-microsecond pulse finishes before heat can spread, so patients recover in days, not weeks. No consumables, no cooling, no anesthetic.

Why Physicians Choose Era Er:YAG Laser Technology
Era is designed to enhance patient outcomes while simplifying your practice. Its innovative features and precision-driven design enable you to deliver exceptional care efficiently and profitably.
Adjustable Fluence and Ablation Depth
Fluence is adjustable across the module range, taking treatment from sub-ablative surface renewal through to deeper full-field ablation. The 2940nm wavelength sits at the peak of water absorption, and the 300-microsecond pulse ablates tissue faster than heat can spread, so depth is set by energy rather than by dwell time.
No Consumables, No Cooling, No Contact
Era requires no disposable tips, no anesthetic, and no contact or cryogen cooling. Full-face resurfacing averages 10 to 20 minutes. Pricing is set against your patient base rather than a disposable cost.

Ablative Resurfacing for All Fitzpatrick Skin Types
Cleared indications include skin resurfacing, acne scar revision, surgical scar improvement, wrinkle reduction, benign lesion removal, age spots, and solar lentigines.
Designed for Delegation
Consistent parameters and a no-contact delivery make treatments safe to delegate to trained staff within scope. No routine maintenance, calibration, or troubleshooting is required.
Simplified Skin Rejuvenation with Powerful Results
Era Elite combines advanced laser technology with patient-centric design, offering safe, effective treatments for smoother, healthier skin. Whether it’s fine lines, scars, or uneven texture, Era Elite makes radiant skin accessible for everyone.
Comfortable Treatments, Lasting Benefits
Pain-free sessions with no need for numbing or cooling, ensuring your treatments are stress-free and convenient.
Visible Results,Minimal Downtime
See real improvements in texture, scars, and pigmentation without disrupting your daily routine.

Built for Every Skin Type
Safe and effective for all skin tones, including darker and sensitive skin, offering inclusive care for every patient.
Skin Health That Stays with You
Era supports both immediate improvements and long-term skin wellness, helping you look and feel your best.
Four Optical Modules,
One Platform
Each Optical Delivery System changes what the same 300-microsecond energy does to tissue. Change the module, change the depth of action. No second device, no second room.
Gentle Resurfacing
10mm

Treats: The everyday treatment. Tone, texture, pigment, fine lines.
Deep Ablative Resurfacing
6mm

Treats: Higher fluence for wrinkles, acne scars, surface pigment.
Hybrid Fractional Ablative Resurfacing
6mm, 16 microchannels

Treats: Collagen remodeling, full-field and fractional in one pass.
Which Era Fits Your Practice
Era Elite runs all four Optical Modules. Era Focus runs the 10mm.
Results That Inspire Trust
Witness the difference Era makes—from smoother skin texture to reduced scars and wrinkles.










Ablative Resurfacing Across Fitzpatrick I–VI
Traditional ablative lasers carry a high risk of post-inflammatory hyperpigmentation in Fitzpatrick IV through VI, which is why most resurfacing platforms quietly exclude those patients.
At 300 microseconds, energy is absorbed by water at the surface rather than lingering in melanin. Controlled ablation leaves little heat behind to trigger a pigment response. The sub-ablative and full-field modules are indicated across Fitzpatrick I–VI.

Technical Specifications

“We’re doing ablative treatments earlier for patients to prevent aging in the future. After the Era treatment patients commonly refer to the treatment as a magic eraser because it takes away the visible signs of aging the patients notice, plus brown spots that are not adequately treated with a lighter treatment such as chemical peels.”
Frequently Asked Questions
The Aerolase Era is a 2940nm erbium (Er:YAG) ablative resurfacing laser platform built on 300-microsecond pulse technology. A single device supports four treatment modes through interchangeable Optical Delivery Systems: sub-ablative AfterGlow, Full-field ablation 10mm and 6mm, and the Hybrid Fractional modules. The 300-microsecond pulse ablates tissue faster than heat can spread, leaving minimal residual thermal damage and reepithelialization within roughly 48 hours.
Each Optical Delivery System changes the depth of action of the same 300-microsecond, 2940nm energy. AfterGlow works sub-ablatively, heating and renewing the surface without an open wound. The 10mm module delivers light full-field ablation and handles most resurfacing volume. The 6mm concentrates the same energy at higher fluence for deeper full-field ablation. Hybrid Fractional adds 16 microchannels reaching into the dermis alongside full-field renewal in a single pulse.
Yes, Er:YAG laser resurfacing is safe on Fitzpatrick IV through VI. At 300 microseconds, energy is absorbed by water at the surface rather than lingering in melanin, and controlled ablation with minimal residual thermal damage reduces the post-inflammatory hyperpigmentation risk that limits traditional ablative lasers in darker skin.
The difference is pulse duration and where the energy goes. CO2 lasers operate at 10,600nm and pulse in the 1 to 10 millisecond range, producing significant thermal damage and 2 to 4 weeks of recovery. Era's 2940nm wavelength sits at the peak of water absorption, more than ten times higher than CO2, and its 300-microsecond pulse ablates faster than heat can spread. The result is minimal residual thermal damage and a recovery measured in days.
Downtime varies by module. AfterGlow results in zero downtime. Full-field resurfacing with the 10mm module typically runs 3 to 5 days with reepithelialization within roughly 48 hours. Higher-fluence 6mm and Hybrid Fractional treatments extend that. For comparison, CO2 resurfacing runs 2 to 4 weeks.
Era's device characteristics support delegation. Parameters are consistent, the handpiece makes no skin contact, no cryogen or contact cooling is involved, and training requirements are minimal. Whether a given treatment may actually be delegated depends on your state's scope-of-practice rules for laser procedures and on your medical director's protocols, which vary considerably. Confirm against your state board before building a delegated model.
See Era in Your Practice
A demo runs about 20 minutes: all four Optical Modules, the parameters for each, and the clinical data behind them.